AGRIWELTDocs Hectare Mini
Reference

Terms used in this manual

ReferenceHectare Mini firmware · 2.2.8

The words of the Hectare Mini manual in one place — from active field and alarm level to singulation, spacing and tramline rhythm.

Term Meaning
Active field The field the panel writes its statistics to now, marked (A). Start a new field
Alarm level In the “Flow” mode: the flow in seeds per second under which a line counts as failing. Drawn as the control line. Set the alarm level
Bout One pass of the drill across the field. Set up the tramline rhythm
Context menu The menu of one device, opened in the sensor setup mode. Interface basics
Control line The white line across a diagram: the alarm level or the target rate drawn.
Doubles Two seeds where one was intended, as a share.
Flow, Hybrid, Precise The three control modes of a diagram. Flow: seeds per second against an alarm level. Hybrid: seeds per metre against a target rate. Precise: seeds per metre with skips, doubles and quality. The section diagram
In control / out of control Whether the panel watches a sensor. A sensor out of control raises no alarms. Take a sensor into or out of control
Lock (work pause) Product application stopped by hand: motors and pump stand still. Lock application by hand
Population Seeds per hectare, shown in thousands (ks/Ha). Derived from the rate, the working width and the number of rows.
Product A material applied by weight, in kg/ha. Up to three: “Product 1” to “Product 3”.
Profile The list of the devices of the machine, set at commissioning. The profile
Quality (singulation) The share of seeds placed singly, as intended — what is left after doubles and skips.
Rate field The figures beside a diagram: measured on top, set value below.
Recalculation interval The stretch of path (or time without a speed sensor) over which skips, doubles, quality and rate are collected before they are shown anew. Set by “Recalculation,m”. A short interval answers quickly but fluctuates; a long one is steadier.
Rhythm The number of bouts and which device shuts off on which bout.
Section, line One seed or fertilizer line with its own sensor: one column of the diagram.
Sensor setup mode The mode in which one device is selected to be switched or set. Hold “MENU”.
Skips A gap where a seed was intended, as a share. Not sown counts the skips over stretches where nothing was sown at all.
Spacing The distance between seeds — the rate per metre turned round.
Target rate What you set: seeds per metre (“Hybrid”, “Precise”), kg/ha (products), L/ha (liquid). The population target follows from it and is not meant to be changed during the field.
Tramline The lane left unsown for the sprayer. Next tramline bout
Unknown area Area driven while a sensor had no connection or was out of control.