AGRIWELTDocs Hectare Mini
Alarms and troubleshooting

Dispenser motor alarms

TroubleshootingHectare Mini firmware · 2.2.8

What the alarms of an electric dispenser motor of the Hectare Mini mean — voltage, temperature, short circuit, current, jamming — and what to check.

The controller of each electric dispenser motor reports its faults to the panel. The device line names the motor: Electric motor: #5. The code of the last fault is on the status screen of the motor, line Last fault: — give it to the service. The motor and its settings: The context menu of a motor.

Alarm text What it means What to check, in this order
“Under voltage” The supply voltage of the motor controller — for the motor or for its electronics — is too low. Battery and alternator of the tractor; the power cable and its connectors; the fuse.
“Over voltage” The supply voltage is too high. The charging voltage of the tractor; the power supply of the system against the data sheet.
“Over temperature” The controller or its heat sink is too hot. Let it cool; a dispenser that runs hard; dirt covering the motor.
“Short circuit” A short on the motor leads — between them, to ground or to the supply. The motor cable and connector; the motor.
“Over current” The motor draws too much current. A dispenser that runs hard or is blocked; the motor.
“Motor jammed!” The motor is told to turn but does not turn. With “Rollback when jammed” at “Yes” it first runs back briefly to free itself. Foreign matter in the dispenser; the drive between motor and dispenser; the motor.
“Device in bootloader!” The motor controller is in its update mode and does not run. Switch the panel and the system off and on. If it stays, call the service.
“FAILURE” Any other fault of the controller. Note Last fault: from the status screen and call the service.

All motors share one more alarm with every device: “Connection lost” — Device does not answer.

Something your machine does that this page does not answer? Write to support@agriwelt.com — an engineer answers.