The two settings of the marker arm sensors of the Hectare Mini — which arm a single sensor watches, and which signal means "down".

Marker sensors tell the panel whether the marker arms are up or down. The home screen draws the two arms; both up are shown yellow — see Indicators. How many sensors watch the arms is set under “Markers” in the profile: “One” or “Both”.

Open the context menu of a marker sensor as in Sensor settings. Both settings need the “Agronomist” level.

Parameter What it does Values · default
“Connected marker” Which arm the single sensor watches: “Left” or “Right”. Shown only with “Markers” at “One”. · “Left”
“Signal "down"” The level on the input, 0 or 1, that means the arm is down. Set it to what the sensor gives with the arm lowered. 0 / 1 · 0

The status screen of a marker sensor shows only the common lines — type, link and alarms (The sensor status screen). A marker sensor raises only the alarms every device can raise: “Connection lost” and “Wrong device type!” — see Device does not answer.

Something your machine does that this page does not answer? Write to support@agriwelt.com — an engineer answers.