Marker sensors
The two settings of the marker arm sensors of the Hectare Mini — which arm a single sensor watches, and which signal means "down".
Marker sensors tell the panel whether the marker arms are up or down. The home screen draws the two arms; both up are shown yellow — see Indicators. How many sensors watch the arms is set under “Markers” in the profile: “One” or “Both”.
Open the context menu of a marker sensor as in Sensor settings. Both settings need the “Agronomist” level.
| Parameter | What it does | Values · default |
|---|---|---|
| “Connected marker” | Which arm the single sensor watches: “Left” or “Right”. Shown only with “Markers” at “One”. | · “Left” |
| “Signal "down"” | The level on the input, 0 or 1, that means the arm is down. Set it to what the sensor gives with the arm lowered. | 0 / 1 · 0 |
The status screen of a marker sensor shows only the common lines — type, link and alarms (The sensor status screen). A marker sensor raises only the alarms every device can raise: “Connection lost” and “Wrong device type!” — see Device does not answer.
Something your machine does that this page does not answer? Write to support@agriwelt.com — an engineer answers.