AGRIWELTDocs Hectare One
Start here

What is supplied

ReferenceHectare One firmware · 1.2.3

The minimum system, the optional devices a machine can carry, and the cables that connect them.

The minimum system is the Hectare One panel and the seed sensors — one sensor per section. Agriwelt seed sensors have their own controller and are connected to the panel directly.

The Hectare One panel.
The Hectare One panel.

Each section of the implement gets its own seed sensor.

Seed sensor for round seed pipes, 25–35 mm.
Seed sensor for round seed pipes, 25–35 mm.

Optional devices

Everything else is optional. What a machine carries is written into the panel's profile.

Device How many What it is for
Pressure sensor Up to three Positive pressure or vacuum.
HUB8 input device As needed Sensors of the “open collector” kind — speed, hopper, fan, dispenser, work position, markers, Wilger flow meters.
Dispenser electric motors With their controller Applying seed or dry fertilizer to the rate.
Tramline actuators Up to four Shutting sections off for the tramline.
Electric pump controller One Liquid fertilizer — UAN, micro-fertilizers and the like.

The inductive sensor below serves two jobs: it measures the travel speed, and it watches that a dispenser shaft is turning.

Inductive sensor for speed and for dispenser shaft rotation.
Inductive sensor for speed and for dispenser shaft rotation.

The HUB8 takes sensors that have no controller of their own and reports each of them to the panel as if it were a device.

HUB8, the eight-channel input device for contact sensors.
HUB8, the eight-channel input device for contact sensors.

One controller design drives the dispenser motors and the liquid fertilizer pump. That is why a machine cannot have a pump without also having the controller a motor would use.

The electric motor controller; the same unit drives the liquid fertilizer pump.
The electric motor controller; the same unit drives the liquid fertilizer pump.

Cables

The panel takes its power through its own supply cable.

Power supply cable of the Hectare panels.
Power supply cable of the Hectare panels.

A HUB8 is joined to the system by a 4-pin Amphenol network cable.

HUB8 network connection cable, Amphenol, 4-pin.
HUB8 network connection cable, Amphenol, 4-pin.

The sensors plug into the HUB8 through a harness.

HUB8 sensor connection harness.
HUB8 sensor connection harness.

Something your machine does that this page does not answer? Write to support@agriwelt.com — an engineer answers.