AGRIWELTDocs Hectare One
Alarms and troubleshooting

Liquid fertilizer pump: pressure and rate alarms

TroubleshootingHectare One firmware · 1.2.3

What to do when the liquid fertilizer pump controller reports too much pressure, a failed pressure sensor, or a rate it cannot hold.

The pump controller is built on the same electronics as the controller of a metering motor. Besides the alarms on this page it raises all the electrical alarms of the metering motor controller — “Short circuit”, “Over current”, “Under voltage”, “Over voltage”, “Over temperature”, “FAILURE” and “Device in bootloader!” — with the same meaning and the same actions: see Metering motor alarms. How the window works: How alarms work.

“High pressure”

What it means. The measured liquid pressure is greater than allowed.

What to do, in this order:

  1. Reduce the travel speed.
  2. In the settings of the pump controller, increase “Max pressure, Bar” — see Liquid fertilizer.

“Pressure sensor failure!”

What it means. The signal from the pressure sensor has gone well outside its 4–20 mA working range.

What to check, in this order:

  1. The connection of the sensor to the controller — the cable and the connector are intact.
  2. The sensor is serviceable. If it has failed, replace it.

The status screen of the pump controller shows the pressure and the raw sensor signal in mA — see The sensor status screen.

“Rate low”

What it means. The pump controller cannot reach the set rate.

What to check, in this order:

  1. The travel speed on the panel matches the real speed and is reasonably steady.
  2. The working load of the pump. Above 90 %: drive more slowly.
  3. Load under 90 %, or jumping strongly: increase “Product rate error,%” in the “Settings” menu — see The Settings menu.
  4. The pump is serviceable.

“Rate high”

What it means. The pump controller applies more than the set rate.

What to check, in this order:

  1. The travel speed on the panel matches the real speed and is reasonably steady.
  2. The working load of the pump. Under 10 %: drive faster.
  3. Load above 10 %, or jumping strongly: increase “Product rate error,%” in the “Settings” menu.
  4. The pump is serviceable.

Something your machine does that this page does not answer? Write to support@agriwelt.com — an engineer answers.