Product rate by weight too low, too high, or impossible
What to do when a product dosed by weight — by an electric motor or a weight-controlled dispenser — misses its target rate, or cannot reach it at all.
These alarms are raised by the system as a whole, not by one device. They exist for each of the four products separately: the number in the message is the number of the product. How the window works: How alarms work.
“Rate of Product 1” / “is too low!” — or — “is too high!”
The same for Product 2, 3 and 4.
What it means. The product is applied below or above its target rate in kilograms per hectare.
Product metered by an electric motor — check, in this order:
- The target rate of the product.
- The speed limits in force, on the status screen of the speed sensor — see The sensor status screen.
- The settings of the electric motor that drives the dispenser shaft — see Dispenser electric motor.
- The metering unit.
- The rotation sensor of the electric motor is serviceable.
- The working load of the motor. Below 20 % or above 80 %, try a metering roller of another size: a larger one if too little is applied, a smaller one if too much.
- Calibrate the metering roller — see Calibrate a metering motor by weight.
Dispenser sensor with “Weight control” switched on — check, in this order:
- The target rate of the product.
- The settings of the dispenser shaft rotation sensor — see Dispenser sensor.
- The metering unit.
- The dispenser sensor is serviceable.
- Calibrate the metering roller — see Calibrate the dispenser by weight.
“Product dosage is” / “impossible! Check product” / “rate and calibration!”
What it means. With the current settings and target rate, the product cannot be applied by weight at all.
What to check, in this order:
- The target rate of the product.
- “Min speed, km/h” and “Max speed, km/h” of the speed sensor — see Speed sensor.
- The settings of the electric motors that apply the products by weight, above all “Minimum, rpm” and “Maximum, rpm”.
- Calibrate the metering rollers of the electric motors.
- If that does not help: fit metering rollers of another size.
Something your machine does that this page does not answer? Write to support@agriwelt.com — an engineer answers.