AGRIWELTDocs Hectare One
Alarms and troubleshooting

Too many doubles or skips

TroubleshootingHectare One firmware · 1.2.3

What to do when a seed sensor of a precision planter counts more doubles or skips than allowed.

Doubles and skips are counted only in the “Precise” mode of seeding — on a precision planter. How the window works: How alarms work.

“High % of doubles”

What it means. The share of doubles the sensor counts is higher than the set limit.

What to check, in this order:

  1. The travel speed on the panel matches the real speed.
  2. “Doubles error,%” in the settings of the seed sensor — is the limit sensible? See Seed and fertilizer sensors.
  3. “Fraction” in the settings of the seed sensor. The value may have to be increased.
  4. The sensor's status on its status screen — see The sensor status screen.
  5. The metering unit: is it serviceable, and is it adjusted correctly?

“High % of skips”

What it means. The share of skips the sensor counts is higher than the set limit.

What to check, in this order:

  1. The travel speed on the panel matches the real speed.
  2. There is enough seed in the hoppers.
  3. “Skips error,%” in the settings of the seed sensor — is the limit sensible?
  4. “Fraction” in the settings of the seed sensor. The value may have to be reduced.
  5. The sensor's status on its status screen.
  6. The metering unit: is it serviceable, and is it adjusted correctly?

Something your machine does that this page does not answer? Write to support@agriwelt.com — an engineer answers.