AGRIWELTDocs Hectare 5
Setting up

The sensor status screen

ExplainedHectare 5 firmware · 1.0.20Draft

How to read the status screen of a sensor — channel, address, type, link state, live figures and active alarms — what each kind of sensor shows on it, and how to move through it by touch.

Reached through “Information” in the context menu of a device (Sensor settings). It shows what the panel knows about one device.

The screen

The status screen of a hopper sensor whose hopper is empty.
  1. “Channel #” — which device of the whole list this is.
  2. The marks either side of the channel number. Swipe left for the previous device, right for the next one. The screen stays open.
  3. “Address:” — the address the device answers on. Not given in this manual.
  4. “Type:” — the kind of device and its number, here hopper sensor 1.
  5. “Link:” — the state of the communication. Table below.
  6. The figures of this kind of device — here the level on the input of a hopper sensor. Table below.
  7. “Alarm 1 from 1” — how many alarms of this device are active.
  8. The name of the alarm — the first of the active alarms.
The status screen of a hopper sensor whose hopper is empty.

Some devices show one more line, “Unit:” — the unit the device is connected to, for example “Control panel” for the travel speed sensor.

Gesture What it does
Swipe right / left Next / previous device — the screen stays open.
Swipe up, or three-finger tap Back to where you came from.
State Meaning
“Normal” The device answers.
“Not controlled” The device is out of control: neither the communication nor anything else is watched.
“No connection” The device does not answer. Red.
“Wrong device type!” Something answers, but not the kind of device the profile expects. Red.
“IMITATION” Speed sensor only: the speed is simulated, not measured. Yellow.

The figures are drawn only while the device is under control, answers, and is of the expected kind. A device out of control shows its identity and nothing else.

What each kind of sensor adds

The status screen of a speed sensor wired to the panel.
The status screen of a speed sensor wired to the panel.
Device What the screen shows
Speed sensor The pulse frequency F= in Hz; with two speed sensors F1= and F2=. Under it the two limits “Min speed, km/h” and “Max speed, km/h”. On a machine that doses a product by weight with electric motors, the limits are those the motors can hold, narrowed by the two settings; a limit the settings cannot meet is written in red as an inequality. Without such motors a limit set to zero is shown as ----, switched off.
Hopper sensor Pin: and the level on the input, "0" or "1".
Dispenser shaft sensor F= in Hz, to three decimals.
Fan sensor F= in Hz.
Pressure sensor P= in kPa.
Seed sensor, dry fertilizer sensor Status: and one of eight states — below.
Liquid fertilizer flow sensor Status: Working, or Working:Tramline in the tramline mode; under it Flow= in L/min.
Work position sensor “Position: Working” or “Position: Transporting”, and Pin: with the level on the input.
Ignition, oil pressure, battery charge, fuel level, air filter Pin: and the level on the input, "0" or "1".
Marker sensor Only the common lines.
Tramline actuator Status: Pulled in, Pulled out, Working while the shutter moves, or Unknown.
Dispenser electric motor Status: Working, or Faulty while any alarm of the motor is active; then “Last fault:” with the controller's code, if there has been one (codes). A universal controller adds IN1[ ] IN2[ ] IN3[ ] with the levels on its three inputs.
Liquid fertilizer pump controller Status: Working or Faulty. With a fault, “Last fault:” and the code. Without one: Flow= in L/min, Load= in per cent, and Pressure sensor: No if there is none, otherwise Pressure sensor= in Bar with the raw signal in mA in brackets. Dashes stand for a value the controller cannot give.

The eight states of a seed or fertilizer sensor

Status Meaning
Working Normal.
Working:Tramline Normal; the sensor is in the tramline control mode for the current bout, or its product application is switched off.
Configuring The sensor has received new settings and is applying them.
Calibration in progress The sensor runs its initial calibration. It takes a few seconds.
Clogged The optical channel is blocked — most likely a blocked seed tube. Red.
Light struck Too much light falls into the optical channel; the sensor may miscount. Red.
Faulty The sensor reports a fault of its own. Red.
Unknown Another fault that cannot be identified. Red.

Something your machine does that this page does not answer? Write to support@agriwelt.com — an engineer answers.