The Settings menu
Every item of the panel's own "Settings" menu — brightness, volume, language, touch sound, diagram settings, date and time, alarm delay, access level — with its range, default and access level.
The “Settings” menu holds the settings of the panel itself. Open it from the home screen: tap with two fingers, then tap “Settings” twice. The settings of the individual sensors are elsewhere — see Sensor settings.

- “Brightness,%” — the backlight. The selected item shows its value between - and +; swipe right or left to change it.
- “Volume” — the loudness of the alarm sound.
- “Language” — the language of the screens.
- “Buttons sound” — a click on every touch the screen takes.
- “Seeding diagram settings” — how the seed diagram is drawn. Below.
- “Change Date&Time” — the clock. Below.
- “Alarm delay” — how long a fault must last before the alarm window opens.
- “User” — the access level. Access levels.
The items
| Item | Range and default | Level |
|---|---|---|
| “Brightness,%” | 0 … 100, in steps of 10; default 100. 0 is the dimmest setting, not off. See Screen brightness. | Operator |
| “Volume” | 0 … 100, in steps of 10; default 100. | Operator |
| “Language” | English, Ukrainian, Polish, Hungarian, Romanian, Bulgarian. | Operator |
| “Buttons sound” | “No” / “Yes”; default “Yes”. | Operator |
| “Seeding diagram settings”, “Fertil. diagram settings”, “Liq.fert. diagram settings” | Submenus. Each is shown only when the machine has a speed sensor, its own sensors are in the profile and its diagram is not in the “Flow” mode. | Operator |
| “Change Date&Time” | Submenu. | Operator |
| “Alarm delay” | 2 … 20 s; default 3 s. See How alarms work. | Operator |
| “Product rate error,%” | 3 … 20 %; default 5 %. How far a product dosed by weight, or the liquid fertilizer pump, may stand from its target before an alarm. Shown only when a product is dosed by weight or a pump controller is in the profile. | Agronomist |
| “Seeding machine parameters” | Submenu: width, modes, tramline, calibrations. Hidden when the machine has neither a speed sensor nor a tramline actuator. Seeding machine parameters | Agronomist |
| “User” | “Operator” / “Agronomist” / “Service”. Enable the Agronomist level | Operator |
| “Reset settings” | Returns the settings to the factory values. | Service |
On a machine with two groups of seed sensors, the two diagram items read “Seeding gr.A diagram” and “Seeding gr.B diagram”.
The settings are stored by themselves a few seconds after the last change. Wait a moment before you switch the panel off.
Diagram settings
There are three of these menus — seed, dry fertilizer, liquid fertilizer. The liquid fertilizer menu has only “Grid” and “Reset to defaults”.
| Item | What it does |
|---|---|
| “Skips & Doubles” | “Yes” shows the skip and double bars over the last stretch of the path. “Precise” mode only. Default “Yes”. |
| “Grid” | “No” — only the rate line; “Partial” — only the tolerance limits; “Full” — both. Default “Full”. |
| “Scale S&D,%” | The height of the skip and double bars, 5 … 50 % in steps of 5; default 20. “Precise” mode only. |
| “Reset to defaults” | Returns this menu to the factory values. Service level only. |
Change Date and Time
Tap “Change Date&Time”, and tap it again. The fields “Year”, “Month”, “Day”, “Hours”, “Minutes” and “Seconds” open, with “Set” at the end.
The date and time fields. Tap a field and swipe right or left until it shows the value you need — one step per swipe. The days follow the month.
Tap “Set”, and tap it again. The clock takes the new values and the “Settings” menu returns.
Leaving the fields with a tap outside the menu, without “Set”, keeps the old time.
Something your machine does that this page does not answer? Write to support@agriwelt.com — an engineer answers.