Application rate too low or too high
What to do when the seed, dry fertilizer or liquid fertilizer sensors report a rate below or above the allowed band, and what NOT UNDER CONTROL means.
The section sensors — seed, dry fertilizer and liquid fertilizer — compare the rate they measure with the target. How the window works: How alarms work.
| Mode of the group | “Under allowable rate” | “Over allowable rate” |
|---|---|---|
| “Flow” | The flow falls below the alarm level — the control line of the diagram. | Not raised. |
| “Hybrid”, “Precise” | The rate falls below the target by more than “Rate error,%”. | The rate rises above the target by more than “Rate error,%”. |
“Under allowable rate”
What it means. A section sensor — seed, dry fertilizer or liquid fertilizer — has measured too little product during work.
What to check, in this order:
- There is enough product in the hoppers or in the tank.
- The travel speed on the panel matches the real speed.
- Seed or dry fertilizer sensor: “Fraction”. The value may have to be reduced. See Seed sensors and dry fertilizer sensors.
- Liquid fertilizer sensor: “Pulses per liter”. The value may have to be reduced. See Liquid fertilizer.
- Seed sensor: its status on the status screen (“Information” in its context menu) — see The sensor status screen.
- The metering unit: is it serviceable, and is it adjusted correctly?
“Over allowable rate”
What it means. A section sensor — seed, dry fertilizer or liquid fertilizer — has measured too much product during work.
What to check, in this order:
- The travel speed on the panel matches the real speed.
- Seed or dry fertilizer sensor: “Fraction”. The value may have to be increased.
- Liquid fertilizer sensor: “Pulses per liter”. The value may have to be increased.
- Seed sensor: its status on the status screen.
- The metering unit: is it serviceable, and is it adjusted correctly?
“NOT UNDER CONTROL” — no window
When rows run under the control line, the home screen shows “NOT UNDER CONTROL” in red and, at the “Operator” level, the alarm sound plays — but no alarm window opens. The rows under the line are not guarded.
What to check, in this order:
- The travel speed on the panel matches the real speed.
- The alarm level of the diagram: is it above the rate the machine really applies? Lower it, or let the panel set it — Set the alarm level.
- There is enough product in the hoppers or in the tank.
- “Fraction” of the seed or fertilizer sensors, or “Pulses per liter” of the liquid sensors — the value may have to be reduced.
- The metering unit: is it serviceable, and is it adjusted correctly?
What the line means: The section diagram.
Something your machine does that this page does not answer? Write to support@agriwelt.com — an engineer answers.